Installation and Maintenance Details of the WFB Seal-less Self-priming Pump

Installation Process

Foundation check: ensure the foundation is flat and strong enough to support the pump and the liquid inside; reinforce if needed.

Pump installation: place the pump on the foundation and fix it with anchor bolts, keeping the pump level with even bolt load.

Pipe connection: connect inlet and outlet pipes matching the pump ports tightly to prevent leaks.

Electrical connection: connect the cable to a power supply matching the rated voltage, ensuring insulation and waterproofing.

Commissioning: fill the pump with water or medium, start it, and check pressure, flow and temperature for normal running.

Maintenance Process

Regular inspection: check the casing, inlet/outlet pipes, cables and connectors, and impeller for cracks, deformation, corrosion, leaks or damaged/aged cabling.

Cleaning: drain the liquid, disassemble and thoroughly clean the pump periodically, then reassemble and refill with fresh medium.

Lubrication: lubricate rotating parts such as bearings and shaft sleeves with oil or grease per the manual.

Troubleshooting: observe and analyze faults, then repair accordingly (replace damaged parts, adjust parameters) while following safe procedures.